Neoprene Glove Test Results

Breakthrough times and permeation rates reported are the average of three test replicates.

ND = No breakthrough time in 8 hours
NA = Not Applicable
NT = Not Tested

All tests performed per ASTM F739-85 by TRI/Environmental, Inc. at ambient temperature for 8 hours. Tests were performed under laboratory conditions and do not represent actual usage conditions. TRI/Environmental makes no warranties or other guarantees concerning protection by these materials and assumes no liability for use of this material with the chemicals tested.

The user should determine the applicability of conditions when assessing suitability of the actual anticipated exposures.

Download a printable version of Neoprene Glove Test Results in PDF format.

ChemicalBreakthrough Time (min.)Permeation Rate (ug/cm2-min.)
1, 1, 1 Trichloroethane23>120
1, 3 Butadiene71>50
Acetic Acid (glacial)NDNA
Acetone49>500
Acetonitrile1209.53
Ammonia gasNDNA
Ammonium HydroxideNDNA
Ammonium NitrateNDNA
Aniline53>17
Carbinol23972
Carbon Disulfide4>500
Chlorine150>50
Chloromethane3968
Chlorothene23>100
Cyclohexanol9713
Diethylamine15>500
Dichloromethane8>500
Dimethylformamide96>500
Ethyl Acetate24>500
Ethyl AlcoholNDNA
Ethylene Oxide40>500
Gasoline14832
Hydrochloric Acid (37%)NDNA
Hydrofluoric Acid (49%)NDNA
Hydrogen ChlorideNDNA
Hydrogen Fluoride (99%)3004.4
Methyl Alcohol23972
Methyl Chloride3968
Methylene Chloride8>500
Methychloroform23>100
Muriatic Acid (37%)NDNA
N-ethylethanamine15>500
Nitrobenzene84>500
Nitropropane88>85
N-hexane57>500
Oleum170>500
PentachlorophenolNDNA
Pentane500.87
Phenol45631
Phenylamine53>17
Potassium Hydroxide (50%)NDNA
Sodium Hydroxide (50%)NDNA
Sulfuric Acid (conc.)NDNA
Sulfuric Acid (fuming)170>500
Tetrachloroethylene48>500
Tetrahydrofuran12>500
Toluene20>500
Xylene25>500
Vinylethylene71>50
guardian-we-protect-hands-green-e1532110121948